Skip to content

English (United Kingdom)Italian - ItalyFrench (Fr)Deutsch (DE-CH-AT)Español(Spanish Formal International)Português (Brasil)
AddThis Social Bookmark Button
Home
TM510FN Professional Coating thickness gauge Print E-mail
tm510fn

The instrument TM510FN is a type of portable measuring gauge, capable of measuring rapidly, nondestructively, and precisely the thickness of coating and cladding material. It is suitable for on site as well as for laboratory uses. Via the using of different probes, many sorts of measuring can be satisfied by the gauge. It can be applied comprehensively to manufacturing, metal processing and chemical profession as well as to commercial inspection. It is indispensable for the major of materials protection.

Features:

  • Two thickness measuring methods adopted, the gauge can be applied to thickness measuring of non-magnetic coating on magnetic metal substrate as well as non-conductive coating on non-magnetic metal substrate;
  • 5 types of probes can be used (F400, F1, F10, N1, CN02,);
  • 2 measuring modes are available: continuing measuring mode (CONTINUE) and single measuring mode (SINGLE);
  • 2 operation modes are available: direct mode (DIRECT) and batch mode (A-B);
  • 5 statistic values:mean value(MEAN), max. value(MAX), min. value (MIN), numbers of measuring (NO), standard deviation (S.DEV)
  • 2 methods can be used to calibrate the gauge, and the system error of the probe can be corrected by use of basic calibrating method;
  • Storage function: 495 measuring values can be stored;
  • Deletion function: delete the single questionable data occurring in measuring, as well as all of the data in memory area to perform the new measuring;
  • Limit can be set: capable of alarming automatically for measuring values out of limit; and a batch of measuring values can be analyzed via histogram;
  • Printing function: measuring value, statistic value, limit and histogram can be printed;
  • Capable of communication with PC: measuring values and statistic values can be sent to PC to perform the further process for data;
  • Indication of low voltage;
  • Buzzing indication in the course of operation;
  • With the function of error warning, error warning can be carried out through display or buzzing;
  • Two shut down modes are available: manual shut down mode and automatic shut down mode;

Technical Data

Measuring range 0-1500µ with standard probe F1.N1 (10.000mm max)
Probes available 5 probes available for F (ferrous: on steel/iron) and N (non-ferrous metals)
Tolerance F1:±(1µ+3%H) N1.±(1.5µ+3% H)
H: actual thickness tested
Resolution Alphanumeric with 4 large digits
Operation language English
Standards DIN, ISO, ASTM,BS
Min. measuring area F1:(standard probe)
Min. curvature radius convex:3mm, concave:50mm
Min. substrate
thickness
type F: 0.5mm, type N: 50mm
Calibration Zero and foil calibration
Statistics Number of measurements, mean, standard deviation,
maximum and minimum of 3000readings
Data memory 500 measuring data
Limits Adjustable with acoustic alarm
Interface USB 2.0
Operating temperature 0-40℃
power supply AA size 1.5V
Dimensions 152×84×34mm (main unit)
Weight 345.g


Kit

Standard

  • Main unit
  • Probe F1 or N1 or both (depending from configuration)
  • 5 Calibration foils
  • Instruction manual
  • Certificate
  • Warranty card
  • Carrying case
  • Communication cable
  • PC software Dataview

Optional

  • 5 probes for different applications
  • Calibration foils in various thickness


Optional Probes

Type F probe :


Probe
F400 F1 F1/90° F10
Measuring Principle Magnetic method
Measuring range(mm) 0~400 0~1250 0~10000
Min resolution(mm) 0.1 0.1 10
Tolerance One-point calibration (mm) ±(2%H+0.7) ±(2%H+1) ±(2%H+10)
Two-point calibration (mm) ±(1%H+0.7) ±((1%H+1) ±(1%H+10)
Minimum radius of curvature (convex) (mm) 1 1.5 flat 10
Minimum measuring area(mm) F3 F7 F7 F40
Minimum thickness of base material(mm) 0.2 0.5 0.5 2

Type N probe :


Probe
N400 N1 CN02
Measuring Principle Eddy current method
Measuring range (mm) 0~400 0~1250 10~200
Min resolution(mm) 0.1 0.1 1
Tolerance One-point calibration (mm) ±(2%H+0.7) ±(2%H+1.5) ±(2%H+1)
Two-point calibration (mm) ±(1%H+0.7) ±(1%H+1.5) --------
Minimum radius of curvature (convex) (mm) 1.5 3 flat
Minimum measuring area(mm) F4 F5 F7
Minimum thickness of base material(mm) 0.3 0.3 0
Note:H——Measured Value